Tempest Cyclone Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Projektory Tempest Cyclone. Tempest Cyclone User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
Cyclone Enclosure User Manual page 1
User Manual and Installation Guide
Tornado Moving Light Enclosures
Tempest Lighting, Inc.
13110 Saticoy Street, Unit C
N. Hollywood, CA 91605, USA
Tel +1 818 787 8984
Fax +1 818 982 5510
www.tempest.org
For all Cyclone projector
enclosures manufactured after
June 2013
Including Cyclone HUSH Enclosures
In the interest of continuous product improvement, the information in this document is subject to change without
notice. Neither Tempest Lighting, Inc. nor its representatives or agents may be held liable for expense or injury
arising from it.
© Tempest Lighting Inc. All Rights Reserved August, 2013
Lamp
Heater Fan RelayOn DMXTemp
ESC OK
User Manual
Przeglądanie stron 0
1 2 3 4 5 6 ... 47 48

Podsumowanie treści

Strona 1 - User Manual

Cyclone Enclosure User Manual page 1 User Manual and Installation Guide Tornado Moving Light Enclosures Tempest Lightin

Strona 2 - Table of Contents

Cyclone Enclosure User Manual page 10 Mounting The Cyclone enclosure is provided with a pair of stainless steel Unistrut channels on the enclo

Strona 3

Cyclone Enclosure User Manual page 11 Stacking Cyclone Enclosures Cyclone enclosures may be stacked, using the Cyclone Stacking Kit accessory.

Strona 4 - Tempest Lighting, Inc.

Cyclone Enclosure User Manual page 12 Cyclovator Tilt Kit Cyclone enclosures are often used on video mapping projects where the angle of the pr

Strona 5 - 1 Introduction

Cyclone Enclosure User Manual page 13 Cyclone HUSH Enclosures Cyclone HUSH enclosures must be provided with an exhaust duct for exhaust air, fr

Strona 6 - Cyclone Outdoor Dimensions

Cyclone Enclosure User Manual page 14 Cyclone HUSH Enclosure Top Surface Dimensions Smaller HUSH Enclosures (8000, 8100 Series) Larger HUSH

Strona 7

Cyclone Enclosure User Manual page 15 Cyclone HUSH Remote Fan Plate 1. Install the Remote fan plate at the end of the exhaust duct, wi

Strona 8 - 2 Installation

Cyclone Enclosure User Manual page 16 3 Wiring  All electrical work must be carried out by a properly licensed electrician, in compliance wi

Strona 9 - Planning

Cyclone Enclosure User Manual page 17 One or Two Power Circuits? Single Feed Split Feed Tempest enclosures may be wired o

Strona 10 - Mounting

Cyclone Enclosure User Manual page 18 Single Feed Operation (factory default) Enclosure and projector share the same electrical circuit. Circu

Strona 11 - Stacking Cyclone Enclosures

Cyclone Enclosure User Manual page 19 Power Connections IMPORTANT Tempest enclosures are supplied for either 120VAC 50/60Hz, or 208-240VAC, 50

Strona 12 - Cyclovator Tilt Kit

Cyclone Enclosure User Manual page 2 Table of Contents 1 Introduction ...

Strona 13 - Cyclone HUSH Enclosures

Cyclone Enclosure User Manual page 20 Auxiliary Power Outlet An auxiliary IEC power outlet is provided for any auxiliary equipment needed (rout

Strona 14

Cyclone Enclosure User Manual page 21 Cyclone 840B Ballast Enclosure Christie Roadie and some Christie Cinema Projectors require a separate Bal

Strona 15 - Remote 2-Fan Plate

Cyclone Enclosure User Manual page 22 Power Connections to 840B Enclosure The 840B enclosure requires a three phase 208V supply in North Americ

Strona 16 - 3 Wiring

Cyclone Enclosure User Manual page 23 4. Place the Christie Ballast in position and secure in place with the tie-down strap provided 5. Plug

Strona 17 - One or Two Power Circuits?

Cyclone Enclosure User Manual page 24 4 Digital Enclosure Control – DEC3.3TM with GoldilocksTM DEC3.3TM – that’s Digital Enclosure Control

Strona 18 - Split Feed Operation

Cyclone Enclosure User Manual page 25 DEC3.3 Schematic Which Controller? The following Table shows which controller is used in different types

Strona 19 - Power Connections

Cyclone Enclosure User Manual page 26 DEC3.3 Main Functions 1 Sense current to projector (lamp on/off) 2 Record lamp hours 3 Monitor tempera

Strona 20 - Auxiliary Power Outlet

Cyclone Enclosure User Manual page 27 Operating Modes DEC3.3 may operate in one of four modes, set using either the Front Panel or by RDM contr

Strona 21

Cyclone Enclosure User Manual page 28 DEC3.3 Control Parameters Temperature and Humidity Ranges: Notes: 1 In moving light enclos

Strona 22

Cyclone Enclosure User Manual page 29 Start-up Validation When you switch power ON to the DEC3.3 controller (firmware 01.00.006 and up), the fo

Strona 23 - Connectors

Cyclone Enclosure User Manual page 3 CERTIFICATE AND DECLARATION OF CONFORMITY FOR CE MARKING Tempest Lighting, Inc. 13110 Saticoy Stree

Strona 24 - Heater Fan RelayOn DMXTemp

Cyclone Enclosure User Manual page 30 termination resistor as detailed in the DMX512 standard. The individual equipment installed inside the T

Strona 25 - DEC3.3 Schematic

Cyclone Enclosure User Manual page 31 Control Interface LED Indicators Heater ON (Green) Heater is ON, to maintain lower temperature le

Strona 26 - DEC3.3 Main Functions

Cyclone Enclosure User Manual page 32 Control Display The display on the Control display provides additional status information, depending on t

Strona 27 - Operating Modes

Cyclone Enclosure User Manual page 33 Control Menu SET DMX OPTIONS SET DMX MODE From the Front Panel, this menu item allows the user to check

Strona 28 - DEC3.3 Control Parameters

Cyclone Enclosure User Manual page 34 NOTE: from firmware revision 0.00.100, DEC holds last valid DMX level if DMX is interrupted. Response De

Strona 29 - DMX Connections

Cyclone Enclosure User Manual page 35 e) Current being drawn by projector/light, in Amps f) Lamp Hours elapsed since last reset g) Firmware

Strona 30 - RDM and RDM Integration

Cyclone Enclosure User Manual page 36 Firmware Upgrade over RDM DEC3.3 firmware is field-upgradeable, using RDM. A field upgrade requires a JE

Strona 31 - Control Interface

Cyclone Enclosure User Manual page 37 5 Mounting the Projector IMPORTANT! READ THIS FIRST  For safety, this must be done by two or more peo

Strona 32

Cyclone Enclosure User Manual page 38 b. For projectors without threaded sockets on the underside, clamps are provided to secure the projector

Strona 33 - Control Menu

Cyclone Enclosure User Manual page 39 5. Return the projector tray into the Cyclone enclosure and check that the lens is aligned with the proj

Strona 34

Cyclone Enclosure User Manual page 4 This is to certify that the following products 8000.US Series Cyclone 8000 Projector Enclos

Strona 35

Cyclone Enclosure User Manual page 40 b. Slide the projector foot clamps in place over the projector feet and tighten the bolts through the pr

Strona 36 - Firmware Upgrade over RDM

Cyclone Enclosure User Manual page 41 Christie Roadie HD35K Projectors These projectors (mounted in Cyclone 8400 enclosures) use an external DC

Strona 37 - 5 Mounting the Projector

Cyclone Enclosure User Manual page 42 6 Closing up the Enclosure 1 Check all electrical connections 2 Clear the enclosure and projector

Strona 38

Cyclone Enclosure User Manual page 43 7 Operation  Outdoor Enclosures must receive power at all times. Enclosure, and will not provide prop

Strona 39

Cyclone Enclosure User Manual page 44 8 Routine Maintenance It is very important to perform routine maintenance on both the enclosure and the

Strona 40 - Airflow Chimneys

Cyclone Enclosure User Manual page 45 Air Filter Replacement The air filters should be removed and checked on a regular basis. We recommend ini

Strona 41

Cyclone Enclosure User Manual page 46 9 Troubleshooting This is a guide to the general symptoms, problems, and solutions that may occur dur

Strona 42 - 6 Closing up the Enclosure

Cyclone Enclosure User Manual page 47 10 Limited Warranty INSPECTION/WARRANTY/RETURNS. A. Customer, at its sole expense, shall inspect al

Strona 43 - 7 Operation

Cyclone Enclosure User Manual page 48 11 Tempest Product Support Step 1: First contact your local Dealer for support. Your dealer is best pl

Strona 44 - 8 Routine Maintenance

Cyclone Enclosure User Manual page 5 1 Introduction Products Covered by this Manual 8000 Series Cyclone 8000 8100 Series Cyclone 8100 810

Strona 45 - Air Filter Replacement

Cyclone Enclosure User Manual page 6 Dimensions, Weights and Projector Fit Cyclone Outdoor Dimensions Note: Cyclone HUSH dimensions are the sam

Strona 46 - 9 Troubleshooting

Cyclone Enclosure User Manual page 7 Open Slide and Door Dimensions A B 8000, 8100 Series, 8102 36”/92c

Strona 47 - 10 Limited Warranty

Cyclone Enclosure User Manual page 8 2 Installation Safety and Warnings These warnings are for your protection. Failure to comply may result

Strona 48 - 11 Tempest Product Support

Cyclone Enclosure User Manual page 9 Planning  Snow clearance:  Observe the following MINIMUM clearances around enclosure for acces

Powiązane modele: Blizzard

Komentarze do niniejszej Instrukcji

Brak uwag